An issue with slipform is dragging. We always try to find solutions for fixing the casting elements robustly. Singular couplers are flimsy (just tied individually to the wall rebar), but coupler boxes are more robust and can resist that drag. COUPLER CADDi is a really good solution for slipform systems.